M4/PIR/Steel

1 – PIR

2 – M4

3 – C Studs

4 – U Track

Compliance with the following codes

  • 2015 and 2012 International Building Code (IBC)
  • 2015 and 2012 International Residential Code (IRC)

Installation – Design:

  •  Must follow, ICC – ES report ESR -3840
  • Must follow, the M-Sips Installation manual
  • Must follow the Steel Stud Manufacturers Association, ICC ES report ESR 3064P

Fire-resistance Assemblies: 

  • To be determined 1st quarter 2020 in accordance with ASTM-E119
  • Polyiso insulation, Class A fire rated in accordance with ASTM E 84
  • M4 sheathing is Non Combustible according ASTM E 136

The building code definition of an approved thermal barrier is one which is equal in fire resistance to 12.7 mm (1/2 inch) gypsum board. All building codes require an approved thermal barrier on the habitable side of a structure between the interior of the structure and the polyurethane foam

Conditions of use

  • Type I, II III or IV exterior walls limited to 40 feet in height

M-SIPs Panel – Specifications (Insulation type Polyiso)

  • R24 – 4.80” x 45” x 8’
  • R38 – 6.81” x 45” x 8’
  • R48 – 8.54” x 45” x 8’

M-Thermo-Panel:

If extended R value is demanded the M-Thermo Panel can be applied as continuous insulation, range: R6 – R19.